LED In-Crosswalk Lighting Systems Some of our recent projects


Enlarge

TS600 Fully Flush
Bidirectional Fixture

TS600
Fully-Flush, Self-Cleaning, Bi-Directional Fixture In-Roadway Warning Lighting Systems

General Description
   The TS600 fixture is designed for In- Roadway Warning Lighting Systems installed in snowplow areas. Their enhanced self-cleaning feature makes them ideal for installations with inclines. And the use of High-bright LED technology makes them the perfect choice for solar powered applications where power consumption must be minimized. The Bi- Directional design allows backlighting of pedestrians in the crosswalk, further improving the pedestrian safety. The TS600 comes standard as a bi-directional fixture, but may be customized to a uni-directional fixture (TS601).

   The TS600 is typically used in crosswalk applications, but is often used in school zone or rail-road crossing, lane control for bridges and tunnels, wrong way warning, and toll booth or toll way leadon applications.

   All In-Roadway Warning Lighting System components are available from TSC. A typical installation would include a set of fixtures, a control system, one or more activation devices such as a pedestrian push button station or pedestrian detection pad, and flashing LED crossing signs.


Enlarge

Application: Two Way,
One Lane Each Way

Why Our TS600 Is Better
Outstanding Durability

  • Corrosion resistant anodized aluminum body provides resistance to traffic wear and weathering.
  • Fully flush profile avoids damage that may be caused by snowplows. High static load rating (44,000 lb.) reduces likelihood of damage from heavy vehicles.
    Superior Visibility and Energy Efficiency
  • Bi-directional design improves visibility of pedestrians in crosswalk.
  • Highbright LEDs are 250 times brighter than the Caltrans minimum standard making them clearly visible in daytime and under the worst weather conditions.
  • Highbright 12 Volt LEDs consume only 6.5 watts/fixture making them ideal for energy efficient solar power applications.
    Low Maintenance
  • Re-usable design reduces the cost, effort and time during resurfacing of the road.
  • Self-cleaning lens design reduces build-up of dirt and need for frequent cleaning.
  • Pre-focused optics eliminates the requirement of field adjustments.
  • Long life LEDs (Average rated life of 10 years) reduces frequency of replacement.
  • Factory sealed optical cartridge design reduces field maintenance issues.
Ordering Codes
Fixture Color/Color Lamp QTY
FI-TS600
Bi-directional Fixture
YY
Y = Yellow
L4: 12V Highbright LED  
FI-TS601
Uni-directional Fixture
YX
X = Blank
L4: 12V Highbright LED  
Notes:
1. Standard fixture operating voltage is 12 VDC. Fixtures may also be operated from 24 VDC in certain applications.
2. TSC supports legacy fixtures with Halogen LA-Q50MR16FL or LED LA-MR16- 18LED-12Y lamps (Special Order).
3. Base Cans (BA-725-10), Base Can Extensions (BA-725-EX-XX), Spacers (BA-725- SP-XX) and Gaskets (BA-725-GSK) are available for the TS600 Fixture.
How to Specify the TS600 Fully-Flush, Self-Cleaning, Bi-Directional Fixture

   The fixture shall be model FI-TS600 as marked by Traffic Safety Corporation or approved equal. In order to be considered equal, the alternate fixture shall satisfy the following requirements.

Construction - The fixture shall be bi-directional and of modular design comprised of a top casting and two (2) pre-focused optical cartridges made of high tensile strength aluminum alloy. The fixture shall be 0.00" above grade when mounted in the factory supplied mounting base. The diameter of the fixture shall not exceed 8" and all mounting hardware shall be stainless steel.

Durability - The fixture shall withstand a static load of 44,000 lb. without sustaining permanent deformation or cracking of materials.Leads, gaskets, etc. shall be rated to withstand 300 degrees F.

LED/Light Cartridge – Each lens shall be molded of high performance optical grade glass and formed in a removable factory
sealed optical cartridge. Two cartridges required per fixture for a total power consumption of 6.5 watts per fixture.

Photometric Performance – The fixture shall have both daytime and nighttime visibility exceeding that of a 50-watt halogen lamp, using a yellow light, 12 Volt, 3.25 watt (with driver) LED Array.

Finish – The fixture shall be anodized natural aluminum and be dark grey in color.

Mounting Base – Fixtures shall be installed in a mounting base (TSC’s # BA-725-10) of high strength steel, hot dip galvanized after fabrication per ASTM-153 specifications, with a 7.25" diameter bolt circle, a 0.75" mud ring, and standard base depth of 10". The base shall be supplied with stainless steel bolts and a plywood cover to protect the mounting flange during installation.The height of the base shall be adjustable using spacers or extensions to facilitate roadway resurfacing.

Warranty - The fixture shall be warranted against defects in workmanship and materials for one year from date of shipment and is eligible for TSC’s 5-Year Limited System Warranty.

TS1000 Crosswalk System Controller

Enlarge

General Description
The patent pending TS1000 is a next generation controller designed from the ground up for superior performance, easy installation and outstanding reliability. Using state-of-the-art microcontroller technology, the TS1000 provides both standard and enhanced user selectable flash patterns:

  • Standard 50 or 60 Flashes Per Minute
  • One of Seven TSC Enhanced Flash Patterns
  • Multi-Flash-Pattern Mode

 

Each Enhanced Flash Pattern is composed of a unique sequence of pulses per flash period and conforms to MUTCD specifications. The Multi-Flash-Pattern Mode continuously cycles through all seven Enhanced Flash Patterns, using a single pattern during each activation period.

The TS1000 supports a wide range of crosswalk system configurations
and is compatible with standard push button, talking push button, pedestrian sensor and other standard activation devices.

Why Our Crosswalk System Controller Is Better
Superior Performance

  • TSC Enhanced Flash Patterns and Multi-Flash-Pattern Mode are designed to maximize pedestrian safety by increasing driver awareness and response to warning systems.
  • Generation of contrasting flash patterns to crosswalk and pre-warning systems is supported by dual DC outputs.
  • Generation of contrasting patterns to distant pre-warning systems is supported by the 120/240 VAC Aux output.
  • An activation override switch provides for continuous flashing during sporting and other high-traffic events.

Easy Installation

  • Conveniently located color coded wiring blocks simplify field wiring and allow easy access during installation.
  • LED status and digital displays allow easy verification of system operation and configuration during setup and testing.
    Outstanding Reliability
  • Internal components are protected by input and output surge protection, circuit breaker and output fuses.
  • Watertight NEMA 4 enclosure with No. 2 cabinet lock provides protection from adverse weather and security from unauthorized access.

How to Specify the TS1000 Crosswalk System Controller
Download Specs (Word format)

The system controller shall be model SC-TS1000 as marked by Traffic Safety Corporation or approved equal. In order to be approved equal, the proposed device must satisfy the following requirements:

1) System controller must support multiple MUTCD compliant regular and enhanced flash patterns and be capable of activating different enhanced patterns per system activation.
2) Output Pattern Operation and Power Limitations:
a. Primary DC Power Output:
i. On 12 VDC models the maximum DC power output of the primary is 96 watts.
ii. On 24 VDC models the maximum DC power output of the primary is 120 watts.
iii. Output pattern selected by pattern selector.
b. Secondary DC Power Output:
i. On 12 VDC models the maximum DC power output of the secondary is 96 watts.
ii. On 24 VDC models the maximum DC power output of the secondary is 120 watts.
iii. Output pattern selected by output mode selector switches:
1- Same as primary; 2- In Sync with primary, but non-enhanced;
3- Non-enhanced complement of primary; 4- Continuous Non-enhanced flashing.
c. Combined DC Power Output:
i. On 12 VDC models the maximum combined power output of the primary plus secondary is 120 watts maximum.
ii. On 24 VDC models the maximum combined power output of the primary plus secondary is 120 watts maximum.
d. AC AUX Power Output:
i. On AC auxiliary output the maximum AC power output is 360 watts.
ii. Output pattern synchronized with secondary DC output pattern.
3) System controller must be based on an integrated, high speed 8-bit microcontroller with non-volatile firmware and memory. All settings must remain intact in loss of power.
4) System controller must include the following controls and indicators:
a. Power Indicator
i. System must include a visual indicator lamp for system power.
b. Activation Duration Setting
i. Must be field adjustable in one second increments.
ii. Must support a range from 1-99 seconds.
iii. Setting must be indicated on digital numeric display.
c. Flash Pattern Setting
i. Must be field adjustable.
ii. Setting must be indicated on digital numeric display.
d. Push Button Test and Indication
i. Must include an internal push button for on-site testing.
ii. System must include visual indicator lamp for internal or external push button or activation device signals.
e. Override Switch
i. Must include an internal switch for constant-on system activation.
f. Output Indicators
i. System must include visual indicator lamps for:
1. System Activation
2. Primary Output
3. Auxiliary Output
5) System must support activation from standard contact-closure type push buttons, talking push buttons and/or pedestrian sensor.
6) System must support a field selected extend option for system activation, to allow or disallow re-triggering of the activation period.
7) System must include an adequate number of clearly labeled and/or color coded terminal blocks for system installation. Terminal blocks must be located to provide adequate access to the installer.
8) System Protection:
a. Input AC voltage must be protected by a thermal/magnetic circuit breaker.
b. DC electronics must be electrically isolated from AC input voltage.
c. AC to DC converter must include transient surge protection or an external transient surge protection device must be used.
d. AC and DC outputs must be protected with replaceable fuse.
e. System must be enclosed in a NEMA 4 rated enclosure or better. System must include a No. 2 cabinet lock or better.